Outside diameter wall thickness and cut length tolerances for carbon aluminized and stainless steel tubes
Technical procurement and manufacturing reference | 17 November 2026 | Units: mm, MPa, mass % unless stated otherwise
Purpose and interpretation
This guide connects raw-material/coil designations with specifications for finished tubes. A grade alone does not define a compliant tube: the purchase order must also identify product form, applicable edition, dimensions, tolerance class, delivery condition, testing, inspection and documentation. Tables are curated commercial grade families, not a reproduction of copyrighted standards or an assertion that every grade ever standardized is included.
Important conformity principle
A comparison such as ASTM 304 ≈ EN 1.4301 ≈ a GOST chromium–nickel grade is a screening aid only. Chemical limits, deoxidation, stabilization, mechanical requirements, permitted processes, heat treatment and tests can differ. Never print an untested alternative standard on an MTC, and never treat a flat-sheet standard as finished-tube certification.
The governing issue
GB/T 13793-2016 specifies longitudinal electric-resistance welded carbon/low-alloy tubes for mechanical, construction and some general service purposes, with PD and PT accuracy classes. The Chinese standard for stainless mechanical welded tubes is now GB/T 12770-2025, effective 1 March 2026; its OD, wall and fixed-length tables changed from the 2012 edition. Do not reuse 2012 numbers under a 2025 certificate.
Material to finished tube norm selection
| Material family | Chinese finished tube standard | Dimensional compliance approach |
|---|---|---|
| Q195/Q235/Q355/08/10/20 carbon | GB/T 13793-2016 | Choose PD.A/B/C and PT.A/B/C plus cut-length category |
| DC01–DC06 formed mechanical tubes | GB/T 13793-2016 only if scope and grades meet norm | Else customer tube drawing / company manufacturing technical specification |
| DX51D–DX56D +AS coated tubes | No automatic conversion from GB/T 36399 coil | Specify finished tube standard/drawing, coating seam treatment and measurement |
| 304/316/321/904L welded mechanical | GB/T 12770-2025 | Use Table 5 OD/WT and 7.7.2.2 length of the 2025 edition |
| 409/430/439/441 stainless welded | GB/T 12770-2025 subject to grade list | Check listed Chinese grade and heat treatment |
| Ferritic heat-exchanger tubes | GB/T 30066-2013 only if current product listing applies | Heat exchanger route and testing differ |
| Fluid-transport stainless welded | GB/T 12771-2019 | Pressure/fluid service has different product requirements |
| Seamless structural carbon | GB/T 8162-2018 | Not an ERW tube standard |
| Seamless stainless | GB/T 14975-2025 | Dimensions and product test requirements by that edition |
GB/T 13793-2016 ERW tube outside diameter tolerance
| Nominal outside diameter | PD.A general | PD.B relatively high | PD.C high precision |
|---|---|---|---|
| 5≤D≤20 | ±0.30 | ±0.15 | ±0.05 |
| 20<D≤35 | ±0.40 | ±0.20 | ±0.10 |
| 35<D≤50 | ±0.50 | ±0.25 | ±0.15 |
| 50<D≤80 | ±1%D | ±0.35 | ±0.25 |
| 80<D≤114.3 | ±1%D | ±0.60 | ±0.40 |
| 114.3<D≤168.3 | ±1%D | ±0.70 | ±0.50 |
| 168.3<D≤219.1 | ±1%D | ±0.80 | ±0.60 |
| 219.1<D≤711 | ±1%D | ±0.75%D | ±0.5%D |
Values are transcribed as condensed brackets from GB/T 13793-2016 Table 1. For unspecified general tube precision, the default is PD.A; conveyor roller tubes have a different default. At D=114.3 mm use the 80–114.3 mm row; D=127 mm falls in 114.3–168.3 mm. D and T nominal sizes follow GB/T 21835 unless otherwise agreed.
GB/T 13793-2016 ERW tube wall thickness tolerance
| Nominal WT | PT.A general | PT.B relatively high | PT.C high precision |
|---|---|---|---|
| 0.50–0.70 | ±0.10 | ±0.04 | ±0.03 |
| 0.70<T≤1.00 | ±10%T | ±0.05 | ±0.04 |
| 1.00<T≤1.50 | ±10%T | ±0.06 | ±0.05 |
| 1.50<T≤2.50 | ±10%T | ±0.12 | ±0.06 |
| 2.50<T≤3.50 | ±10%T | ±0.16 | ±0.10 |
| 3.50<T≤4.50 | ±10%T | ±0.22 | ±0.18 |
| 4.50<T≤5.50 | ±10%T | ±0.26 | ±0.21 |
| T>5.50 | ±10%T | ±7.5%T | ±5%T |
Wall Table 2 contains important product/grade and wall nonuniformity notes: the general PT.A shorthand ±10% applies to ordinary non-conveyor ERW cases across listed bands except the 0.50–0.70 mm row, while the higher precision columns are absolute millimetre tolerances for common thin-wall products. For buyer certification, use the original Table 2 footnotes and confirm how weld reinforcement is excluded.
GB/T 13793 cut length and production precision
| Length category / OD | Requirement | Interpretation |
|---|---|---|
| Usual length D≤30 | 4,000–6,000 mm | Random length, not precise cut |
| Usual length 30<D≤70 | 4,000–8,000 mm | Random length |
| Usual length D>70 | 4,000–12,000 mm | Random length |
| Measured/multiple D≤219.1 | +10/−0 mm | Specified within usual-length range by agreement |
| Measured/multiple D>219.1 | +50/−0 mm | Specified within usual-length range by agreement |
| Multiple lengths | 5–10 mm cutting allowance per division | Must be specified in PO |
| Unusual 1197/1198/3000 cut lengths | Explicit agreement needed | May be secondary cutting, outside usual-length rules |
Worked tolerance limits for Dumai round tubes under GB/T 13793
| D × T × L | PD.A OD | PD.B OD | PD.C OD | PT.A WT | PT.B WT | PT.C WT | Cut L |
|---|---|---|---|---|---|---|---|
| 76.2 × 1.5 × 5840 | ±0.76 | ±0.35 | ±0.25 | ±0.15 | ±0.06 | ±0.05 | +10/−0* |
| 101.6 × 2 × 5840 | ±1.02 | ±0.6 | ±0.4 | ±0.2 | ±0.12 | ±0.06 | +10/−0* |
| 101.6 × 1.5 × 3000 | ±1.02 | ±0.6 | ±0.4 | ±0.15 | ±0.06 | ±0.05 | +10/−0* |
| 114.3 × 1.5 × 1198 | ±1.14 | ±0.6 | ±0.4 | ±0.15 | ±0.06 | ±0.05 | +10/−0* |
| 127 × 1.5 × 5800 | ±1.27 | ±0.7 | ±0.5 | ±0.15 | ±0.06 | ±0.05 | +10/−0* |
| 129.6 × 1.5 × 3000 | ±1.3 | ±0.7 | ±0.5 | ±0.15 | ±0.06 | ±0.05 | +10/−0* |
| 152.4 × 2 × 5840 | ±1.52 | ±0.7 | ±0.5 | ±0.2 | ±0.12 | ±0.06 | +10/−0* |
| 219 × 2 × 5800 | ±2.19 | ±0.8 | ±0.6 | ±0.2 | ±0.12 | ±0.06 | +10/−0* |
*Measured-length GB/T 13793 tolerance only when the ordered piece length is within its usual-length category and otherwise qualified. In particular 1,198 and 3,000 mm pieces typically require an agreed secondary-cutting specification even though their mill-produced mother tube can meet GB/T 13793. Values are calculations from the grade-independent dimensional class tables; they do NOT certify DX+AS or stainless grades to GB/T 13793.
GB/T 12770-2025 stainless mechanical welded tubes
The currently effective GB/T 12770-2025 substantially revised outside diameter and wall tolerances in Table 5 and fixed-length requirements in clause 7.7.2.2. An accessible authoritative table excerpt with verified numeric entries was not established here. Thus this document does not assign invented OD, WT or L values to 304, 316, 409 or 441 under GB/T 12770-2025. Before quotation with a “GB/T 12770-2025” claim, the engineering department must consult the official Table 5 and clause 7.7.2.2, select the accuracy and tube conditions, then insert the actual tolerances on the drawing and quotation.
| Grade group | Reference tube standard | OD tolerance | Wall tolerance | Cut length |
|---|---|---|---|---|
| 304/304L/316/316L/321 | GB/T 12770-2025 | Table 5; grade, OD and condition dependent | Table 5; grade/condition dependent | Clause 7.7.2.2 |
| 409/409L/430/439/441 | GB/T 12770-2025 only if grade listed | Table 5; verify ferritic listing | Table 5; verify delivery condition | Clause 7.7.2.2 |
| 409AL aluminized ferritic | Qualified substrate + customized coated-tube spec | Drawings; no blanket GB tube value | Drawing / coating measurement rule | Drawing, plus-cut rule |
Why the 2025 edition matters
GB/T 12770-2012 was withdrawn on 1 March 2026. The national standards record for GB/T 12770-2025 explicitly says its diameter/wall Table 5 and fixed-length requirements were changed. If a customer submits the older standard, ask for authorization to quote to that historical edition and mark it visibly; a new certificate should normally use the effective edition.
Production quality checks
Outer diameter and ovality
Measure two perpendicular OD directions and record extrema at representative positions outside end distortions. Compare to the purchased PD class for GB/T 13793 or actual GB/T 12770-2025 Table 5.
Wall thickness
Check at several angular positions outside the weld bead. Base steel wall and coating thickness must be separately identified for aluminized tube.
Cut length
Measure after end facing or saw cutting. Record a unilateral +x/−0 limit as such, with minimum and maximum in mm.
Weld and testing
Confirm HF/ERW, laser or TIG route is allowed by the product standard, and carry out flattening, bend, eddy or UT according to that standard/PO.
Traceability
Record heat/coil/tube batch, GB/T product standard edition, exact grade, dimensional class, actual minimum and maximum results.
Sources and edition confirmation
GB/T 13793-2016 original dimensional tables: https://www.botopsteelpipe.com/uploads/GB-T-13793-2016.pdf
GB/T 12770-2025 current registry: https://std.samr.gov.cn/gb/search/gbDetailedCNF?id=3DBA213285520D16E06397BE0A0A8119
GB/T 12771-2019 national register: https://std.samr.gov.cn/search/stdPage?q=12771
GB/T 30066-2013 registry: https://openstd.samr.gov.cn/bzgk/std/newGbInfo?hcno=8E8A29443077D553A8715E4E60723D57